Water ingress after extension
We have water ingress in our house, we had a flat roof which started to leak, we have had a pitched roof erected to replace the flat roof and all was fine for approx 10 months, we now have the water ingress again, this all started after we had an extension, a wall was erected at the end of the flat roof, what the builder hadn’t taken into account was the fall of the flat roof ran this way and water started to gather, we presumed the pitched roof would remedy this and as I said it had seemed to for 10 months, the wall I mention has paving tiles at the very top and the breeze block below is exposed to the elements, my question is, could the water be soaking into these and making it’s way in to the property this way?
=================
Answer:-
Yes, water ingress through exposed breeze blocks is definitely a plausible cause of your problem. Breeze blocks (concrete blocks) are porous and can absorb significant amounts of water, especially when directly exposed to weather without proper protection.
Here’s what’s likely happening:
Water absorption pathway: Rain hits the exposed breeze blocks, which absorb water like a sponge. This moisture can then travel through the blocks and mortar joints, eventually finding its way into your interior walls and causing damp patches or visible water ingress.
Why it worked for 10 months: The blocks may have initially been relatively dry after construction, but over time they’ve become saturated with repeated exposure to rain. Once saturated, they lose their ability to dry out quickly between weather events.
The paving tiles issue: While paving tiles on top provide some protection, they’re not designed as a weatherproof cap for walls. Water can still get underneath them or through joints, and they don’t protect the vertical faces of the blocks below.
Solutions to consider:
- Apply a breathable masonry sealer or waterproof coating to the exposed breeze blocks
- Install proper coping stones with drip edges instead of paving tiles
- Add cavity trays or other damp-proof barriers if structurally feasible
- Ensure adequate drainage away from the wall base
You should have a damp specialist or structural surveyor assess the situation properly, as they can determine the exact moisture pathway and recommend the most appropriate waterproofing solution for your specific construction details.
==========================
Contact Us :
(0)20 3987 4923
Mob: 07404960364
info@vrltd.uk
566 Chiswick High Street, W4 5YA, London