We have a landing, 3 bedrooms, a bathroom and a loft. 2 bedrooms have power to the lights and they come on, but the landing, 1 bedroom, bathroom and loft lights don’t come on. The connection to the light on the landing has been dodgy for 2 years, and is connected to the hall downstairs for one of the switches. This connection to downstairs also doesn’t work, but the rest of the switches on the 3 way switch (2/3)also work. I’ve checked for loose connections in the socket on the landing and there are none, and I’ve also checked the light itself and there doesn’t seem to be anything loose. I also checked the power in all the switches that are off and there is no power at all. What could be the problem? Randomly the landing light started flickering for a few seconds last night but hasn’t since.
======================
Answer;-
Let me help analyze this electrical issue systematically:
Key symptoms:
1. Multiple upstairs lights not working (landing, 1 bedroom, bathroom, loft)
2. Known history of dodgy landing light connection
3. Landing light flickered briefly last night
4. No power detected at affected switches
5. Three-way switch system partially working (some switches functional, others not)
6. Two bedrooms still have working lights
Given these symptoms, here are the most likely causes:
1. Most Probable: Failed connection at a junction box
– The pattern of multiple lights failing in the same area suggests a common connection point has failed
– The history of the dodgy landing connection and recent flickering points to a deteriorating connection that has finally failed completely
– This would explain why some circuits work while others don’t
2. Second Possibility: Tripped circuit breaker or blown fuse
– However, this seems less likely since some lights are still working
3. Third Possibility: Break in the wiring
– Could be in the walls/ceiling, particularly near the landing area
– The flickering before complete failure supports this possibility
SAFETY WARNING: Given that this involves multiple circuits and has been an ongoing issue, I strongly recommend hiring a qualified electrician to investigate. Electrical issues can pose serious fire risks, especially with:
– Intermittent connections (like your flickering light)
– Multiple circuits affected
– Long-term deteriorating connections
In the meantime:
1. Check your circuit breaker box if you haven’t already
2. Don’t attempt to modify any wiring yourself
3. Monitor for any burning smells or other signs of electrical issues
4. Consider using portable lighting in affected areas until fixed
==========================